The furnace of an oil fired boiler should be () before the operating burner is lit.
相似题目
-
Which of the actions listed should be taken FIRST to control an oil fire in a fuel oil tank?()
-
Fuel oil tanks must be fitted with () that can be closed rapidly and remotely in the event of an emergency such as a fire.
-
The longer an oil fire is permitted to burn, the ().
-
When fighting an oil or gasoline fire in the bilge,which of the following should NOT be used?()
-
The forced draught fan should be started and air passed through the furnace for several minutes to “()” it of any exhaust gas or oil vapors.
-
The ability of an oil to separate cleanly from an oil and water mixture is referred to as its ().
-
The FIRST course of action in fighting a fire in a cargo or fuel oil tank is to ().
-
The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()
-
A large oil fire on the deck of a ship can be fought most effectively with().
-
Improper maintenance of the fuel oil burners in an automatically fired auxiliary boiler, could result in ()
-
The max effluent of the oil content from a ship of 400 tons gross tonnage and above other than an oil tanker is().
-
The FIRST step to take in fighting an engine room fire resulting from a ruptured fuel oil service line, is to ().
-
Too much air in the furnace of an oil-fired boiler would be indicated by ().
-
The operating water is supplied under the ()of an oil separator.
-
The ()is not a component of an oil separator.
-
A distorted furnace in a fire-tube auxiliary boiler may be the result of ()
-
When an oil fire has been extinguished, the surface of the oil should be kept covered with foam to prevent ().
-
The fire of fuel oil is classified as() fire.
-
The defective places in the furnace () with fire bricks.
-
You are transferring fuel from the storage tanks to the day tanks by means of an electric fuel oil transfer pumpIf the pump motor catches fire, you would FIRST ().
-
Fueling results in the collection of waste oil in drip pans and containers. Which is an approved method of disposing of the waste oil? ()
-
As for an oil-fired boiler if at a normal steaming condition and water goes out of sight in gauge glasses the action you should take is: () (1) secure oil to fires (2) increase feed pump pressure
-
Which of the listed fire extinguishers is recommended for use on an electrical switchboard fire?
-
As for an oil-fired boiler if at a normal steaming condition and water goes out of sight in gauge glasses the action you should take is: (1) secure oil to fires; (2) increase feed pump pressure.
推荐题目
- 《电力安全工作规程(发电厂和变电站电气部分)》规定:在带电的电磁式或电容式电压互感器二次回路上工作时,应防止二次侧短路或接地。()
- 有关急性梗阻性化脓性胆管炎的叙述,哪项是错误的()
- 登记时如果识别仪不能正常工作,可以临时手工进行录入。
- 焦炭的气孔率指焦炭气孔所占的体积与焦块体积之比,它可以借测得的焦炭的真比重与假比重的值来求得,其计算公式为()。
- 为了保证旋耕机作业时刀轴两端受力对称,耕后地表平整,旋耕机刀片的安装普遍采用()。
- 南方电网一体化电网运行智能系统管理信息大区原则上划分()。
- 在高电压的交流电路中,必须使用()将高压转为低压。
- “一带一路”建设要充分发挥现有()等双边机制作用,协调推动合作项目实施。
- 企业技术创新主要表现在
- 需要根据具体情况确定合适的防烟分区大小,每个防烟分区的面积不宜大于()。